The catalog of COLORTERM presents all the materials of COLORTERM, with which LLC "COLORTERM" works.
LLC "COLORTERM" can guarantee you quality and long service life.
TEMPERATURE SENSOR (EExd) PTD-100
The PTD-100 sensor is specially designed to improve data transfer from the sensor sensor to the electronic controller. The sensor design makes it possible not to use additional spark barriers when the sensor itself is located in an explosive zone, and the controller is installed in a non-explosive zone. The sensor can be connected to junction boxes marked with explosion protection EExe or EExd and is used together with controllers such as TS-014, TC8165 or other types of electronic controllers.Accuracy of measurements:The grounded stainless steel outer shell prevents the spread of electromagnetic radiation, which affects the accuracy of the sensor reading.Protected construction: Each PT-100 sensor has an outer shell, made of stainless steel, so that the sensor cannot be damaged by the sharp edges of the metal thermal insulation casingApproved for use in hazardous areas:The PTD-100 sensor is suitable for use in explosive zones without spark-proof barriers. The sensor can be connected to junction boxes marked with explosion protection EEx e or EEx d. The latter should have a volume less than 100 cm3.
Conductor cross sectionMaximum length of the signal cable, km1.5 mm
1,0 km
2.5 mm
1,7 km
4.0 mm
2,7 km
Local temperature controller ZT-C-...-P-WP and ZT-C-...-P-XP
The ZT-WP and ZT-XP thermostats are designed to control the electric heating system by controlling the surface temperature of a pipe or tank in electric heating circuits that provide protection against freezing of pipelines and tanks. Each thermostat is presented in four temperature modifications and ranges of temperature exposure to the sensor. The ZT-WP model is designed for wall mounting (or pipe mounting using a single stainless steel mounting bracket 1) and has a flexible PVC casing for a galvanized steel sensor with an oil seal and a device for passing through the insulation. The ZT-XP model includes a mounting column that simplifies the installation of the thermostat directly on the pipe and provides for the input and connection of two heating cables inside the housing. ZT terminators are designed for use in normal (not classified) areas and are certified according to ATEX for use in explosive areas of Category 2 and 3 (Zone 1 and 2) for use in Category 2 and 3 (Zone 1 and 2).
ELECTRONIC CONTROL MODULE FOR ELECTRIC HEATING ECM
The ECM terminator is an electronic control module specially designed to control heating systems that provide protection against freezing of pipelines and tanks. The ZT-WP model is designed for wall mounting (or pipe mounting) using a single stainless steel mounting bracket. The ZT-XP model includes a mounting column that simplifies the installation of the thermostat on the pipe and provides for the insertion and connection of two heating cables inside the housing. Housing material ECM reinforced glass-reinforced polymer, dust moisture protection class IP66.The ECM provides connections of two sensors: a temperature control sensor and a temperature limiter sensor. In the standard version, ECM reports the temperature of the pipeline (tank) to the RS-485 physical network using the Mod-Bus RTU communication protocol. In addition, there are two communication options: CAN-Bus or 4-20mA. ECM terminators are designed for use in normal (not classified) areas and are certified according to ATEX for use in explosive areas of Category 2 and 3 (Zone 1 and 2)). ECM-OS is available in a stainless steel box case for use in marine environments.
SHD-SEAThe dispatching board is designed for monitoring and controlling electric heating supply circuits, obtaining data on the operation of the system, signaling the parameters of heating lines.SHU-SEOThe cabinet is designed for distribution and protection of power supply circuits of electrical equipment, transmission of data on the operation of the system, signaling parameters of heating lines.The amount of automation according to the TOR:- measurement of ambient air temperature;- measurement of surface temperature;- measurement of electrical network parameters (current, voltage, power);- alarm of an accident by phases from each feeder;- alarm system electric heating "on";- temperature sensor malfunction alarm;- electric heating control mode:- automatic, manual mode, modulation mode (automatic switching from manual mode);- visualization of electrical network data, the temperature of the heated object, emergency modes;- protection against leakage and short-circuit currents;- power off when the permissible parameters of leakage currents increase;- development of software according to the TOR on the basis of software complexes for tank heating, anti-pooling systems, pipeline heating, etc.;- AVR, Partitioning;
Control panel, type CPB.CPB type panels are the basic control panels of Caloritech ™ , which are used to interface with electric heaters equipped with remotely located thermostats, limit value protection devices, percentage value timers and other control components. An introductory disconnector is not included in the scope of delivery of this model. The delivery package includes:Weatherproof housing with hinged doorMagnetic contactors with fusesOn/Off switch and indicator lightTransformer of the control circuit with fuses with a secondary voltage of 120 VTerminal clips for connection of remotely located control devicesControl panel, type CPA.The fully equipped CPA control panel is suitable for use with various electric heaters. The delivery package of the CPA series control panel includes:Housing Type 4, weatherproof, with hinged doorsDisconnector with locking when opening the doorTransformer of the control circuit with fuses with a secondary voltage of 120 VOn/Off SwitchMagnetic contactor for a specific purpose with a fuseDigital configurable microprocessor Temperature control Unit (UT320 series)Electronic upper limit shutdown device with manual or automatic resetIndicator lights "System on", "Heating on", Upper temperature limit".