Self-regulating heating cables

Self-regulating heating cables

The catalog of COLORTERM presents all the materials of COLORTERM, with which LLC "COLORTERM" works.

LLC "COLORTERM" can guarantee you quality and long service life.

BSX Series
BSX self-regulating heating cables provide frost protection and process temperature maintenance for metal and non-metal pipelines, tanks and equipment. The output thermal power of the BSX cable varies according to environmental conditions along the entire length of the circuit. When the heat losses of the insulated pipeline, tanks or equipment increase (for example, due to a drop in ambient temperature), the output thermal power of the cable increases. Conversely, with a decrease in heat losses (due to an increase in temperature or product movement), the output thermal power of the cable decreases. The possibility of self-regulation of high-frequency cables allows you to avoid temperature damage to the cable in places of overlap. BSX cables are designed for use in ordinary (unclassified) areas and are certified according to the ATEX and TRTS standard for use in explosive areas of Category 2 and 3 (Zone 1 and 2).
More detailed
RSX Series
The RSX 15-2 self-regulating heating cable is designed for use in situations where specific power requirements do not allow the use of standard heating cables. RSX 15-2 self-regulating heating cables provide frost protection and process temperature maintenance for metal and non-metal pipelines, tanks and equipment. The output thermal power of the RSX 15-2 cable varies according to environmental conditions along the entire length of the circuit. When the heat losses of the insulated pipeline, tanks or equipment increase (for example, due to a drop in ambient temperature), the output thermal power of the cable increases. Conversely, with a decrease in heat losses (due to an increase in temperature or product movement), the output thermal power of the cable decreases. The possibility of self-adjustment of RSX 15-2 cables allows you to avoid temperature damage to the cable in places of overlap. RSX 15-2 cables are designed for use in ordinary (unclassified) areas and are certified according to the ATEX and TRTS standard for use in explosive areas of Category 2 and 3 (Zone 1 and 2).
More detailed
KSX Series
High-performance self-regulating heating cables LYCH are specially designed to protect against freezing at high heat losses and maintain the temperature of the process. The output thermal power of the cable varies according to environmental conditions along the entire length of the circuit. When the heat losses of the insulated pipeline, tanks or equipment increase (for example, due to a drop in ambient temperature), the output thermal power of the cable increases. Conversely, with a decrease in heat losses (due to an increase in temperature or product movement), the output thermal power of the cable decreases. The possibility of self-regulation of cables allows you to avoid temperature damage to the cable in places of overlap. The cables are designed for use in conventional (unclassified) and certified according to the standard, ATEX and TRTS for use in explosive areas of Category 2 and 3 (Zone 1 and 2) explosive zones.
More detailed
HTSX Series
HTSX high-performance self-regulating heating cables are designed specifically to protect against freezing at high heat losses and maintain the process temperature associated with steaming. The output thermal power of the cable varies according to environmental conditions along the entire length of the circuit. When the heat losses of the insulated pipeline, tanks or equipment increase (for example, due to a drop in ambient temperature), the output thermal power of the cable increases. Conversely, with a decrease in heat losses (due to an increase in temperature or product movement), the output thermal power of the cable decreases. The possibility of self-regulation of cables allows you to avoid temperature damage to the cable at the intersection points. The cables are designed for use in conventional (unclassified) and certified according to the standard, ATEX and TRTS for use in explosive areas of Category 2 and 3 (Zone 1 and 2) explosive zones.
More detailed
VSX Series
VSX high-performance self-regulating heating cables are designed specifically to maintain process temperature and frost protection in environments where high temperatures are required. VSX cables are designed to work in an environment with a high exposure temperature associated with steaming.VSX high-performance self-regulating heating cables are designed specifically to maintain process temperature and frost protection in environments where high temperatures are required. VSX cables are designed to work in an environment with a high exposure temperature associated with steaming.
More detailed
Constant power FP
Parallel resistance heating cables of constant power FP provide frost protection and temperature maintenance in pipelines, tanks and equipment. The parallel resistance design allows you to cut the cable and make its end sealing directly at the installation site using easy-to-use Thermon kits supplied with cables.FP cables provide stable output power regardless of the length of the circuit. Since FP cables are not exposed to inrush current surges associated with self-regulating heating cables, there is no need to use power distribution equipment with increased rated characteristics.FP cables are certified for use in normal (not classified in any category) zones and in potentially explosive environments in accordance with ATEX, TRTS, RMRS and the IEC Ex certification system.
More detailed